How to Smooth Voltage Fluctuations in Inverters?

09/05/2025 Visits: 8

How to Smooth Voltage Fluctuations in Inverters? Filter Circuit Types & VFD Applications

In the inverter (Variable Frequency Drive, VFD) industry, stable DC-link voltage is the core guarantee for reliable motor operation and precise speed control. Voltage fluctuations in the DC-link—caused by the pulsating output of the rectifier circuit or sudden load changes—can trigger VFD overvoltage/undervoltage protection, damage IGBT modules, or lead to motor speed instability. As the “voltage stabilizer” of inverters, filter circuits play a critical role in “smoothing” these fluctuations. This article focuses on inverter-specific filter solutions, their working principles, and practical application guidelines, tailored to the needs of industrial electrical engineers, VFD maintenance personnel, and equipment buyers.
How to Smooth Voltage Fluctuations in Inverters

I. Inverter-Specific Filter Solutions: Matching Scenarios to Performance Needs

Inverters vary widely in power rating (from 0.75kW to 400kW+) and load characteristics (light/heavy, constant/variable), so filter circuit selection must align with application scenarios. Below are the three most common filter schemes in the VFD industry, along with their “smoothing” mechanisms and on-site adaptation:

1. Capacitor Filter: The Core Solution for Medium-and Small-Power VFDs

Capacitor filters are used in 90% of medium-and small-power inverters (1.5kW–55kW) (e.g., VFDs for fans, water pumps, and conveyors). They act as “electrical energy reservoirs” to smooth DC-link voltage through rapid charging and slow discharging.

How It “Smooths” Fluctuations

  • After three-phase rectification (380V AC input), the raw DC output has 6x grid frequency pulsations (≈300Hz), with a voltage fluctuation range of ±30V (peak DC ≈540V).
  • A large-capacity electrolytic capacitor (typically 2200μF–10,000μF/450V) is connected in parallel across the DC-link:
    1. When the rectified voltage rises above the capacitor’s current voltage, the capacitor charges quickly to store energy, “catching” the voltage peak.
    2. When the rectified voltage drops below the capacitor’s voltage, the capacitor discharges slowly to supplement the DC-link, filling voltage troughs.
  • Result: Voltage fluctuations are reduced from ±30V to ±5V, and the DC-link remains stable enough for IGBTs to output high-quality PWM signals.

Inverter-Specific Design Tips

  • Capacity Selection: Follow the industry rule of thumb: “200μF–300μF per kW of VFD power.” For example, a 15kW VFD requires 3000μF–4500μF (add a 2–3x margin to avoid overload).
  • Component Type: Choose “high-frequency low-impedance (ESR ≤50mΩ)” electrolytic capacitors. Ordinary capacitors cause excessive heat, leading to 30% of DC-link failures (e.g., capacitor bulging or leakage).
  • Scene Optimization: In high-temperature environments (e.g., summer industrial workshops), parallel a 100nF high-frequency ceramic capacitor with the main electrolytic capacitor and upgrade to 105℃-rated capacitors—this extends the capacitor lifespan from 2 years to 5 years and reduces overvoltage faults by 80%.

2. Inductor Filter: Stabilizing Heavy-Power VFDs Under Load

Inductor filters are essential for high-power VFDs (200kW+) (e.g., VFDs for machine tool spindles, elevator traction motors, and rolling mills). They leverage Lenz’s Law (“opposing current changes”) to suppress voltage fluctuations caused by large current surges.

How It “Smooths” Fluctuations

  • High-power VFDs often face sudden load spikes (e.g., during elevator startup: the load jumps from 0 to rated current in 0.5s, reaching 500A+). Without inductors, capacitor-only filters cannot respond quickly enough, causing the DC-link voltage to drop from 540V to 480V and triggering undervoltage protection.
  • An iron-core inductor (1mH–5mH) is connected in series with the DC-link:
    1. When the load current surges, the inductor generates a back EMF to slow current changes, preventing abrupt voltage dips.
    2. It flattens current fluctuations from ±50A to ±10A, indirectly stabilizing the voltage.
  • Result: Voltage fluctuations during heavy-load startup are reduced from ±15V to ±2V, and the protection tripping rate drops to 0.5%.

Inverter-Specific Design Tips

  • Inductor Parameters: Ensure the saturation current is ≥2x the rated VFD current to avoid magnetic saturation under overload. For a 315kW VFD (rated current 600A), select an inductor with a saturation current ≥1200A.
  • Combination with Capacitors: For ultra-stable output, use “inductor + capacitor” (LC) filtering: the series inductor first suppresses current spikes, then the parallel capacitor smooths residual ripples.

3. π-Type LC Filter: Precision Smoothing for Servo VFDs

π-Type LC filters (capacitor → inductor → capacitor) are used in precision servo VFDs and machine tool VFDs (requiring motor speed accuracy of 0.01r/min). They eliminate micro-ripples to avoid motor low-speed crawling or vibration.

How It “Smooths” Fluctuations

  • Servo VFDs demand DC-link ripple voltage ≤5mV (vs. ±5V for standard VFDs). A single capacitor or inductor cannot achieve this level of precision.
  • The π-type structure works in three steps:
    1. First capacitor (e.g., 4700μF): Filters high-frequency ripples (1kHz+) from the rectifier.
    2. Series inductor (e.g., 2mH): Suppresses medium-frequency current fluctuations (100Hz–1kHz).
    3. Second capacitor (e.g., 1000μF): Eliminates residual low-frequency ripples (<100Hz).
  • Result: Ripple voltage is reduced to ≤2mV, and the PWM waveform distortion rate is ≤1%—ensuring the motor vibration amplitude drops from 0.1mm to 0.02mm.

Typical Application Case

  • The Delta VFD-MS300 series (a servo VFD for precision lathes) uses a π-type filter (2200μF + 1mH + 1000μF). This design improves speed accuracy to 0.005r/min, meeting the requirements of high-precision machining (e.g., aluminum alloy parts with ±0.001mm tolerance).

II. Solving Common VFD Pain Points with Filter Optimization

Voltage fluctuations often cause on-site VFD failures. Below is a troubleshooting table linking industry pain points to filter solutions, verified by real-world data:

 

VFD Industry Pain Point Filter Optimization Solution Effect Verification
Medium-small VFDs (1.5kW–37kW) frequently trigger “DC-link overvoltage” in summer Parallel a 100nF high-frequency ceramic capacitor with the main filter capacitor; replace with 105℃-rated electrolytic capacitors Capacitor lifespan extended from 2 to 5 years; overvoltage fault rate reduced by 80%
High-power VFDs (110kW+) trigger undervoltage protection during heavy-load startup Add a 3mH iron-core inductor in series with the DC-link; increase the main capacitor capacity by 20% Voltage fluctuation reduced from ±15V to ±3V; protection tripping rate dropped to 0.5%
Servo VFDs cause motor “low-frequency vibration” (≤500r/min) Replace the single-capacitor filter with a π-type LC filter (2200μF + 1mH + 1000μF) Motor vibration amplitude reduced from 0.1mm to 0.02mm; speed accuracy improved to 0.005r/min

III. Industry Standards & Authoritative References

To ensure filter design compliance and reliability, adhere to the following VFD-specific standards and resources:

 

  • Chinese National Standard: GB/T 37973-2019 Technical Requirements for DC-Link Capacitors for Inverters (specifies ripple current tolerance ≥1.5x the rated VFD current).
  • International Standard: IEC 61800-5-1 Adjustable Speed Electrical Power Drive Systems – Safety Requirements (requires inductor saturation current ≥2x the rated current).
  • Brand Guidelines:
    • Siemens S120 series (high-power VFDs): Uses “dual capacitors in parallel + series inductor” (2×4700μF/450V + 2mH) for 200kW–400kW rolling mill applications, achieving ±1% voltage stability.
    • Mitsubishi FR-A800 series (medium-small VFDs): Adopts “high-frequency low-resistance capacitor + ceramic capacitor” filtering, with a ripple suppression rate up to 95% for fan/pump loads.

IV. VFD Filter Circuit Selection Guide

Use the table below to quickly match filter schemes to VFD specifications:

 

VFD Power Range Recommended Filter Scheme Core Component Parameters (380V Input) Suitable Load Types
0.75kW–37kW Single capacitor filter (parallel) 1000μF–4700μF/450V (high-frequency low-impedance electrolytic capacitor) Fans, water pumps, conveyors
45kW–160kW LC filter (series inductor + parallel capacitor) 4700μF–10,000μF/450V + 1mH–3mH iron-core inductor Machine tool spindles, compressors
185kW+ π-Type LC filter (dual capacitors + series inductor) 10,000μF×2/450V + 3mH–5mH iron-core inductor Elevator traction motors, rolling mills

Conclusion

Filter circuits are the “hidden backbone” of stable VFD operation. For medium-small power, cost-sensitive applications, choose capacitor filters with high-temperature and low-impedance components. For heavy-power, high-reliability scenarios, use LC filters to suppress current surges. For precision servo systems, opt for π-type LC filters to eliminate micro-ripples. By aligning filter design with VFD power, load, and environmental conditions, you can reduce 70% of DC-link-related failures and ensure long-term, efficient motor operation.

 

For further DC-link design details, refer to Infineon’s Inverter DC-Link Design Guide (https://www.infineon.com/) or use Murata’s Capacitor Selection Calculator (https://www.murata.com/) to verify component parameters.